Project Spotlight · Jeffersonton, VA

Two Systems, One Upgrade: Attic and Basement in Jeffersonton

Both systems were low on refrigerant and had no water safety on the drains. We replaced them with Trane variable speed equipment.

Heat PumpDual Fuel / HybridAir HandlerFurnaceTraneJeffersonton
New Trane gas furnace and coil installed in a basement in Jeffersonton, VA

What did this Jeffersonton homeowner get?

We replaced both HVAC systems in the home. The attic got a new Trane variable speed heat pump and air handler. The basement was converted to a dual fuel hybrid: a Trane heat pump that switches to a Trane gas furnace when it gets cold outside. Both systems now have drain safety.

A Jeffersonton home had two aging systems, one in the attic and one in the basement. Both were low on refrigerant, and neither had a water safety device on the condensate drain.

What We Found

In the attic, readings pointed to a low refrigerant charge. The outdoor unit had a worn contactor, the condenser coil was starting to clog, and a UV air system was disconnected and not running.

The basement system was also low on charge, and its condenser coil was dirty. The filters in use were restricting airflow. On both systems, there was no water safety on the drain. We recommended replacing them both.

Old air handler in a Jeffersonton, VA attic before replacement
The old air handler in the attic before replacement.

What We Did

In the attic, we installed a new Trane XV20i variable speed heat pump (3 ton) on a new pad with snow legs, plus a new Trane variable speed air handler with a heater kit. We converted the existing copper lines to the government-mandated R-454B refrigerant, enlarged the hallway return, sealed the new duct connections, and added an EZ Trap drain safety device.

In the basement, we converted the system to a hybrid. Outside, a Trane XV20i heat pump. Inside, a Trane S9V2 two-stage gas furnace with an LP conversion kit and a new coil. The system is set to switch from the heat pump to gas heat at 40°F. We remounted the humidifier, added a media filter box, and tested both systems. Each one got a Trane Link 360 Wi-Fi thermostat.

Old air handler in a Jeffersonton, VA attic before replacement
The old air handler in the attic before replacement.
New Trane variable speed air handler installed in a Jeffersonton, VA attic
The new variable speed air handler in the attic.
Finished Trane dual fuel furnace install in a Jeffersonton, VA basement
The finished basement furnace install.

What Changed for the Homeowner

Both levels of the home now run on matched Trane variable speed equipment. The basement system uses the heat pump in milder weather, then the gas furnace takes over when it gets cold. Both systems have drain safety that was not there before.

What this means for you

  • Heat and cooling from new, matched Trane systems on both levels.
  • A basement hybrid that picks the right fuel based on the weather.
  • Drain safety to help protect the home from water leaks.
Why a dual fuel system matters: A heat pump handles milder weather efficiently. When it gets cold, the gas furnace takes over. In this home, that changeover is set at 40°F.

Heat Pump and Dual Fuel Work You Can Count On

Our NATE-certified technicians install heat pumps and dual fuel systems across Culpeper County, Fauquier County, and Northern Virginia, from the first estimate to the final test.

Technical details

Equipment

  • Trane XV20i variable speed heat pump, 3 ton (attic)
  • Trane XV20i variable speed heat pump (basement)
  • Trane Link variable speed air handler with 10 kW heat kit (attic)
  • Trane S9V2 two-stage gas furnace, 80k BTU, LP conversion (basement)
  • 2× Trane Link 360 Wi-Fi thermostats
  • EZ Trap condensate water safety (attic)
  • R-454B refrigerant conversion on both systems

Scope of work

Attic: We removed the old system and installed a Trane XV20i variable speed heat pump (3 ton) with a WeatherGuard top on a new pad with snow legs, plus a new fused disconnect. We flushed, purged, and pressure tested the existing copper lines to convert them to R-454B refrigerant, added a filter drier, and confirmed there were no leaks. Inside, we installed a Trane Link variable speed air handler with a 10 kW heater kit, reconnected the media air cleaner box, enlarged the hallway return to 16 inches, sealed new duct connections, flushed the drain lines, and added an EZ Trap water safety device.

Basement: We converted the system to a hybrid with a Trane XV20i heat pump with a WeatherGuard top outside, and a Trane S9V2 two-stage gas furnace (80k BTU) with an LP conversion kit, variable speed blower, and relay panel inside. We installed a new coil, media filter box, and supply transition, sealed the new duct connections, remounted the humidifier on the supply plenum, and set the changeover from heat pump to gas at 40°F. Both systems received a Trane Link 360 Wi-Fi thermostat and were tested.